Skip to product information
1 of 1

MEDTRONIC GUARDIAN SENSOR 3

MEDTRONIC GUARDIAN SENSOR 3

Regular price $28.99 USD
Regular price Sale price $28.99 USD
Sale Sold out

Medtronic Guardian Sensor 3


The Medtronic Guardian Sensor 3 is a next-generation continuous glucose monitoring (CGM) sensor that provides real-time glucose readings for individuals with type 1 and type 2 diabetes. When paired with Medtronic insulin pump systems, the Guardian Sensor 3 helps optimize blood glucose control by delivering accurate, real-time glucose data and enabling automated insulin adjustments. Its advanced technology offers precise glucose measurements to help minimize both hyperglycemia (high blood sugar) and hypoglycemia (low blood sugar), improving overall diabetes management.

Key Features:

  • Real-Time Glucose Monitoring: The Guardian Sensor 3 continuously measures glucose levels, providing real-time data every 5 minutes. This helps users make informed decisions about insulin doses and lifestyle adjustments to maintain optimal glucose control.

  • High Accuracy: The Guardian Sensor 3 delivers highly accurate glucose readings, helping to reduce the need for fingerstick calibrations. It works seamlessly with Medtronic insulin pumps to adjust insulin delivery based on real-time glucose data.

  • Small and Discreet Design: The sensor is small, lightweight, and discreet, designed to be worn comfortably under clothing without interfering with daily activities. Its compact size makes it easy to wear while going about your routine.

  • Sensor Life: The Guardian Sensor 3 is designed for up to 7 days of continuous use, providing reliable glucose data for a full week before needing to be replaced.

  • Sensor Accuracy and Calibration: The Guardian Sensor 3 is engineered to minimize errors and offer superior sensor accuracy. Unlike some earlier models, this sensor requires fewer calibrations and is designed to maintain reliable performance even in challenging conditions.

  • Integration with Medtronic Pump Systems: When paired with a Medtronic insulin pump, the Guardian Sensor 3 enables SmartGuardβ„’ technology to automatically adjust basal insulin delivery every 5 minutes, helping to maintain glucose levels within a target range with minimal user intervention.

  • Alerts and Alarms: The Guardian Sensor 3 provides customizable alerts for both high and low blood sugar levels, as well as trends such as rapid glucose changes. This helps users take action before blood sugar levels become dangerously high or low.

  • Predictive Alerts: In combination with Medtronic pump systems, the sensor can provide predictive alerts to warn of potential highs or lows before they occur, allowing users to take preventive action to avoid glucose fluctuations.

  • Seamless Data Transmission: The sensor transmits glucose data directly to a compatible Medtronic insulin pump or CareLinkβ„’ software, enabling users to track trends, review data, and adjust their diabetes management plan with their healthcare provider.


How It Works:

  1. The Guardian Sensor 3 is inserted under the skin, where it continuously measures glucose levels in the interstitial fluid (fluid between cells).

  2. The sensor transmits glucose data to a compatible Medtronic insulin pump or receiver, providing real-time information every 5 minutes.

  3. The data from the sensor is used to calculate insulin delivery, either manually or through SmartGuardβ„’ automation, ensuring timely adjustments to basal insulin.

  4. The sensor’s alerts will notify the user of any high or low glucose readings, helping to prevent dangerous glucose excursions.

  5. Over the course of its 7-day lifespan, the Guardian Sensor 3 provides continuous glucose monitoring to guide insulin dosing and other aspects of diabetes management.

Important Information:

  • Sensor Replacement: The Guardian Sensor 3 needs to be replaced every 7 days. It is essential to ensure proper sensor placement and secure attachment to maximize accuracy and reliability.

  • Compatibility: The Guardian Sensor 3 is compatible with a range of Medtronic insulin pumps and may also work with CareLinkβ„’ software for data tracking and remote monitoring.

  • Use With Medtronic Systems: To access full functionality, the Guardian Sensor 3 must be used with a Medtronic insulin pump that supports CGM integration. Always refer to your pump’s instructions for compatibility and setup.

  • Accuracy and Calibration: The Guardian Sensor 3 is factory-calibrated, which means it requires fewer fingerstick calibrations compared to previous models. However, your healthcare provider may recommend occasional calibrations to maintain optimal accuracy.

  • Storage: Store the Guardian Sensor 3 at room temperature before use, and do not expose it to extreme temperatures or humidity. Follow the manufacturer's instructions for proper sensor handling and storage.

  • Allergy Considerations: The sensor's adhesive is designed for skin compatibility, but users with sensitive skin or allergies should consult their healthcare provider for alternatives if needed.

Precautions:

  • Skin Sensitivity: If any irritation occurs at the sensor insertion site, remove the sensor and consult your healthcare provider. Avoid using the sensor if you have known skin allergies to adhesives.

  • Maintenance: Ensure the Guardian Sensor 3 is inserted and maintained according to the manufacturer's guidelines to ensure accurate glucose readings. Any issues with sensor readings should be reported to your healthcare provider for troubleshooting.

  • Not for Intravenous Use: The Guardian Sensor 3 is designed for subcutaneous glucose monitoring only and should not be used for intravenous glucose measurements.

Additional Information:

  • The Medtronic Guardian Sensor 3 is designed to integrate seamlessly with Medtronic's insulin pump systems and CareLinkβ„’ software, providing a comprehensive diabetes management solution that enables both proactive and reactive adjustments to insulin therapy.

The Medtronic Guardian Sensor 3 offers a highly accurate and reliable solution for continuous glucose monitoring, helping individuals with type 1 and type 2 diabetes manage their blood glucose levels more effectively, with less effort and fewer fingersticks. It plays a vital role in Medtronic's closed-loop system, providing users with peace of mind and improved glucose control through real-time data and automated insulin adjustments.

Product features

Materials and care

Merchandising tips

View full details
Your cart
Product Product subtotal Quantity Price Product subtotal
MEDTRONIC GUARDIAN SENSOR 3
MEDTRONIC GUARDIAN SENSOR 3
MEDTRONIC GUARDIAN SENSOR 3
$28.99/ea
$0.00
Sold out
$28.99/ea $0.00